Frame size configuration – EXFO FTB-8500 Series for FTB-500 User Manual

Page 507

Advertising
background image

Pop-Up Windows

Ethernet and Fibre Channel Application

493

Frame Size Configuration

Frame Size Configuration

This pop-up window is only available with EtherSAM (Y.1564) test case.

Type: For Data profile, select Fixed (default), Random, or EMIX frame
size. The Type is set to Fixed for Video and Voice profiles.

Size and EMIX Frame Sizes:

For Fixed type with Data service profile, select the frame size. The
size is not configurable and set to 1374 for Video and 138 for
Voice.

For EMIX type, enter up to 8 frame size values depending on the
quantity selected (see Quantity on page 494). The default frame
sizes are 64, 128, 512, 1024, 1518, 1518, 1518, and 1518. However,
the minimum frame size will be adjusted according to the frame
structure and components selected. See tables below for
components that may affect the minimum frame size value. The
EMIX frame sequence will be repeated until the test ends.

For Fixed and EMIX types, the frame size range is as follow.

Test

10 Mbit/s

100/1000 Mbit/s and 10 Gbit/s

EtherSAM

64

a

to 10000

a.

The minimum frame size will be adjusted according to the frame structure and

components selected.

64

a

to 16000

EtherSAM DTS 68

a

to 10000

68

a

to 16000

Advertising