Installation, 8 installing the command unit, 9 installing the heat pump – Glow-worm Clearly Heat Pumps 14kW User Manual

Page 16

Advertising
background image

0020117819_01 - 05/11 - Glow-worm

- 14 -

8 Installing the command unit

Make sure that the materials used for performing the

installation are compatible with those of the appliance.

Determine the place of assembly. See the chapter "Location".

3

3

1

1

4

2

Key

1 Mounting

screw

2 Wall

support

3 Rawlplug

4 Electric terminal block

Separate the command unit from the wall support (3).

Pass the electrical connection cables through the hole on the

left of the connector and connect them onto terminal (4). See

the chapter "Installation examples".

Position the support (3) on a wall.

Drill holes for the fi xing screws in accordance with the 2 fi xing

holes on the wall support (3).

Insert the rawlplugs (2) in the holes.

Fix the support (3) with the fi xing screws (supplied).

2

1

Key

1 Command

unit

2 Wall

support

Assemble the command unit (1) on the wall support (2).

9 Installing the heat pump

9.1

Scope of delivery

1

3

4

2

2.1

2.2

2.4

2.3

2.2

2.4

2.3

3.1

3.2

Key

1

Heat pump

(x1)

2

Packet of accessories

(x1)

2.1 Condensate

connection

(x1)

2.2 Leak-tight seal for passing mains and low-voltage

cables

(x2)

INSTALLATION

Advertising