Installation – Glow-worm Clearly Heat Pumps 14kW User Manual

Page 32

Advertising
background image

0020117819_01 - 05/11 - Glow-worm

- 30 -

Code Function

Description

Setting

Factory

setting

Modifi able

parameter

Min

Max

1

Default functioning

mode

Choose the default functioning mode for the heat pump:

0 = Stopped

2 = Cooling

3 = Heating

0

3

0

Yes

2

Protection against frost

Function to protect the installation against frost when the heat pump is stopped.

1 = Deactivated

2 = Activated

1

2

1

Yes

3

Temperature triggering

protection against frost

Choose the ambient temperature of the dwelling from which the installation's

protection against frost is activated.

6°C

12°C

6°C

Yes

4

Correction of the

ambient temperature

This parameter lets you correct the heat pump's temperature setting by

increasing or reducing the temperature of the water in the installation to improve

the adjustment of the ambient temperature of the room.

-5°C

+5°C

0°C

Yes

5

Silent mode

This mode lets you reduce the noise emitted by the heat pump (at night, for

example), by reducing the frequency at which the compressor functions.

1 = Deactivated

2 = Activated

1

2

1

Yes

6

Compressor frequency

reduction

This parameter defi nes the percentage reduction of the compressor frequency.

50% 100%

75%

Yes

7

Temperature of the

dwelling

This parameter displays the current temperature level:

1 = Temperature Comfort

2 = Temperature Night

3 = Temperature Eco

1

3

-

No

8

Ambient temperature

setting

This parameter displays the ambient temperature setting when you press one of

the buttons "Comfort", "Night" and "Eco".

12°C 38°C

-

No

9

Ambient temperature

This parameter displays the ambient temperature of the room measured by the

sensor installed in the command unit.

-20°C 50°C

-

No

10

Humidity rate

This parameter displays the rate of humidity of the room measured by the sensor

installed in the command unit.

0

100

-

No

11

Exterior temperature

This parameter displays the exterior temperature measured by the heat pump.

-30°C 90°C

-

No

12

Not used

13

Correction to the

ambient temperature

(command unit

position)

This parameter corrects the measurement of the ambient temperature following

an error in positioning the command unit.

-5°C

+5°C

0°C

Yes

14

Programme time

intervals

Choose the number of time intervals available for weekly programming:

2 = 2 time intervals

4 = 4 time intervals

6 = 6 time intervals

2

4

6

Yes

15

"Comfort" heating

temperature

Choose the ambient temperature in heating mode for the "Comfort" temperature. 12°C 38°C

20°C

Yes

16

"Comfort" cooling

temperature

Choose the ambient temperature in cooling mode for the "Comfort" temperature. 12°C 38°C

24°C

Yes

17

"Night" heating

temperature

Choose the ambient temperature in heating mode for the "Night" temperature.

12°C 38°C

18°C

Yes

18

"Night" cooling

temperature

Choose the ambient temperature in cooling mode for the "Night" temperature.

12°C 38°C

26°C

Yes

19

"Eco" heating

temperature

Choose the ambient temperature in heating mode for the "Eco" temperature.

12°C 38°C

15°C

Yes

20

"Eco" cooling

temperature

Choose the ambient temperature in cooling mode for the "Eco" temperature.

12°C 38°C

28°C

Yes

21

Ambient temperature

setting

This parameter displays the ambient temperature of the room where the

command unit is installed.

12°C 38°C

-

No

22

Displaying fault codes

This parameter displays the last occurring fault code.

-

-

-

No

23

Fault history

Every 4 seconds, this parameter displays the latest fault codes that appear.

-

-

-

No

15.2.4

Reinitialisation of parameters

This function is used to reinitialise the control box parameters

(factory settings).

b

The return to factory settings is irreversible. All the

personalised settings of the control box will be lost.

Press the 2 buttons ( ) and (M) for 10 seconds.

When selecting for the fi rst time, the fi gure 999 appears in the

temperature display area and the fi gure 10 appears in the time

display area.

Hold down the ( ) button until 0 is displayed on the screen.

The message “FD” is displayed in the temperature area.

The control box then restores the factory default parameters.

Restart the entire system to complete the restore.