Installation – Glow-worm Clearly Heat Pumps 14kW User Manual

Page 25

Advertising
background image

0020117819_01 - 05/11 - Glow-worm

- 23 -

- weather resistant.

- equipped with wires adapted to appliance’s power rating.

Connect the heat pump to an electrical panel via an

independent protection system (diff erential breaker with at

least 3 mm between each contact). See the table below.

Additional protection may be required during installation to

ensure buff er category II.

The power supply cut-off devices must allow complete

disconnection of the power under the conditions required for

over-voltage category III.

Description

Unit

7

12

14

Electricity supply

V-ph-

Hz

230 - 1 - 50

Acceptable voltage range

V

207/254

Maximum power absorbed

kW

2.7

5.1

5.1

Maximum current

A

14

23

20

Power fuse (gL)

A

15 Type B 25 Type D 25 Type D

Maximum current in glycol

pump

A

2

13.1 Access to main board

B

A

A

A

C

2

1

Key

1 Terminal blocks for 230 V and 12 V connection

2 Front

panel

Remove the fastening screws (A).

Slide the front panel (2) downwards (B) and pull it towards

yourself (B) using the handle.

To close the appliance, carry out the operations in reverse order.

13.2 Cable

passage

e

The low and mains voltage cables must be inserted in

diff erent sleeves.

2

1

Key

1 Mains-voltage cable passage

2 Low-voltage cable passage

Insert the electrical power cables in passages (1) and (2)

provided for this purpose.

Make sure that the electrical cables are not in contact with the

compressor and the hot pipes.

Fix the electrical cables with the clamps installed inside the

heat pump.

13.4 Electrical

wiring

3

2

4

1

Key

Recommended cable section

1

230 V power cable

H07RN-F 3 x 2.5 mm²

2

12 V cable

0.75 mm²

3

230 V cable (outputs 2A

maximum)

0.75 mm²

4

Connection cable for the

command unit

4 x 0.75 mm²

INSTALLATION

Advertising