2.4.2

In defrosting and cooling mode

2

1

3

4

5

6

Key

1 Finned heat exchanger

2 Reverse

cycle

valve

3 Ventilating

fan

4 Compressor

5 Pressure

regulator

6 Exchanger with plates

2.4.3

Min. and Max. temperature settings in heating

60
50

70

40

45

30
20
10

0

-20

-10

0

10

20

30

A

B

Key

A Water

temperature

B Air

temperature

2.4.4

Min. and Max. temperature settings in cooling

12

14

16

18

20

10

8
6
4
2
0

0

10

20

30

40

50

46

A

B

Key

A Water

temperature

B Air

temperature

2.4.5

Principle for controlling the heat pump

Control using the Glow Worm control unit. This confi guration is

recommended in the case of an installation with the Glow Worm

hydraulic unit. The Glow Worm system of active management of

the heat pump using dry 12V contacts. The command unit is used

only as a confi guration tool.