Installation, 4 board of power 14kw – Glow-worm Clearly Heat Pumps 14kW User Manual

Page 29

Advertising
background image

0020117819_01 - 05/11 - Glow-worm

- 27 -

13.5.4

Board of power 14kW

R

C

W

C

A

B

C

W

R

G

W

R

1TB

230V  1~  50Hz

L

N

2TB

1

2

3

J4.1 / /2.10

J3.1 / /2.03

J1.1 / /2.08

U

V

W

 

63CF

1

2

64CF

1

2

CN400
(WHITE)

CN300
(WHITE)

CN609
(BLUE)

CN610
(YELLOW)

CN604
(WHITE)

CN603
(WHITE)

CN602
(YELLOW)

CN601
(WHITE)

CN600
(WHITE)

CN710
(WHITE)

SW802

SW804

SW803

ON

ON

ON

4
3
2
1

4
3
2
1

4
3
2
1

SW801

CN704
(BLUE)

SW800

RY704

P04

CN701
(WHITE)

P05

CONTROL P.C. BOARD
MCC1571

P06

CN04
(WHITE)

P07

CN200

F03
T10A,250V~

F01
T25A,250V~

CN201

P01

L/F

P02

CN202

P09

10CM

1

2

11CM

1

2

 

 

49C

1

2

L

N

65CF

1

2

3

66CF

1

2

67CF

1

2

68CF

1

2

3

69CF

1

2

70CF

1

2

71CF

1

2

3

72CF

1

2

3

4

5

6

73CF

1

2

3

4

74CF

1

2

3

4

5

6

75CF

1

2

3

1TD

1TS

1TL

1R

2R

2FM

1FM

1CM

1TE

1TO

1RV

1PVM

Key

1RV

4-way cycle inversion gate

1TL

Temperature sensor for the fi nned heat exchanger

1TD

Compressor discharge temperature sensor

1TS

Temperature sensor for compressor suction

1TE

Temperature sensor for plate to plate exchanger

1TO

Exterior temperature sensor

1CM

Compressor

1FM

Fan 1

2FM

Fan 2

1R

Filtering coil 1

2R

Filtering coil 2

1PVM

Electronic expansion unit