Maintenance, 18 servicing, 19 replacement of parts – Glow-worm Clearly Heat Pumps 14kW User Manual

Page 38: 20 spare parts

Advertising
background image

0020117819_01 - 05/11 - Glow-worm

- 36 -

18 Servicing

To ensure the continued effi cient and safe operation of the

appliance it is recommended that it is checked and serviced as

necessary at regular intervals. The frequency of servicing will

depend upon the particular installation conditions and usage.

Servicing/maintenance should be carried out by a competent

person approved at the time by the Health and Safety

Executive in accordance with the rules in force in the countries

of destination.

To obtain service, please call your installer or Glow-worm’s

own service organisation.

After servicing, complete the relevant Service Interval Record

section of the Benchmark Checklist located on the inside back

pages of this document.

b

IMPORTANT: any action carried out on the refrigerant

circuit must be performed by qualifi ed authorised

personnel.

The refrigerant fl uid contains gases that, when released into the

atmosphere, may aff ect the environment by depleting the ozone

layer, contributing to the greenhouse eff ect and an increase in

temperature. The risk of leakage cannot be excluded for devices

intended to operate for many years and subject to the eff ects of

the environment.

See the "Safety instructions" chapter for a list of operations to

be performed prior to the maintenance of the application.

Once the maintenance operations have been completed,

consult the ¨Start Up¨ chapter to restart the appliance.

Annual Maintenance

Check the proper functioning of safety devices.

Check the pressure of the water system.

Check that there are no traces of rust or oil around the cooling

circuit’s components.

Ensure that the appliance’s components are neither worn nor

broken.

Check that the wires are fi rmly attached to the electrical

terminals.

Check the appliance’s earthing.

Check the starting temperature of the heat pump and the

adjustment points.

Check for any ice in the compressor.

Remove any dust from the power supply.

Clean the air / refrigerant battery and make sure that air

circulates between the fi ns and around the unit.

Check that the fan rotates freely.

Check the pressure of the expansion vessel.

19 Replacement of Parts

Do not use reconditioned or copy parts, only use original parts

supplied by Glow-worm.

If a part is required, contact the Glow-worm service organisation.

Please quote the name and serial number of the appliance,

this information will be on the data plate on the side of the

appliance.

If in doubt seek advice from the local gas company or

Glowworm’s own service organisation.

a

Replacement of parts must be carried out by a

competent person approved at the time by the Health

and Safety Executive.

19.2.1

Mains supply cable

e

The main supply cable must be replaced by a

qualifi ed and competent electrician.

If the main supply cable is damaged, replace it refering to the

chapter "Electrical connection".

20 Spare parts

In order to guarantee the safe and prolonged life of the product,

manufacturers genuine spare parts must be used.

i

This appliance displays a CE Mark of conformity. Only

use the manufacturer’s genuine, new spare parts.

Ensure that spare parts are correctly mounted in the right

position and direction. After fi tting any spare part or servicing,

the appliance must be tested for its safe operation.