14 Fault Finding

DIAGNOSTIC CODES - LEVEL 1
Installer Access

14725

Diagram 14.8

d.99 State List

(see diagram 14.7)

d.28 Option Relay 2

d.27 Option Relay 1

d.91 Internal Programmer type (for use with Options board kit) 0:24 hour (default) 1:7 day

N/A

Flow temperature setpoint

Description

Range

intelligent control

Status additional heating pump (option)

Status central heating pump

> 8 no flame < 4 good flame

Minutes

Digital regulator status

Quantity (in hundreds)

N/A

Reserved for future use

To enter the diagnostics menu follow the procedure below:-

Press and hold the ‘MODE’ and ‘+’ buttons for approx 5 seconds until the screen changes. Use the ‘+’ or ‘-’ button to select the

number 96, this is the password. Hold the ‘MODE’ for approx 5 seconds when 96 is selected, when the screen changes release

the button. The screen will flash between ‘L1’ and a number. ‘L1’ indicates you have level 1 access, the number indicates

the diagnostic number below. Use the ‘+’ and ‘-’ to cycle through the selections below. To select a diagnostic number press

the ‘MODE’ button when the correct number is selected. The display will show the parameter value of the diagnostic number

selected. To return to the diagnostic number selector simply press the ‘MODE’ button. To change the parameter use the + or

- buttons. Once the value has been changed it must be saved by holding the ‘MODE’ button for approximately 5 seconds. This

will return to the diagnostic number selector.

Indicates read and write function - all other diagnostics are read only