15 replacement of parts, 16 access to user interface and main pcb, 17 control box – Glow-worm Flexicom hx User Manual

Page 56: 19 installer interface electrical cartridge

Advertising
background image

56

Diagram 15.8

13003

15 Replacement of Parts

Diagram 15.9

13003

Diagram 15.10

13004

15.15 Casing Seal

Refer to Section 13.8.

15.16 Access to User interface and Main

PCB

For access, refer to section 15.1.
Hinge down the control box and unclip the rear cover to gain

access.
Remove electrical connections from main PCB noting their

positions for replacement.
Unclip main PCB and remove, see diagram 15.8.
Unclip user interface and remove.
For replacement, see diagram 15.9 and ensure that the user

interface connection cable is refitted.
NOTE: When re-fitting any of the control boards make sure

you support the control box to avoid straining hinges as you

push down and clip back into place.

15.17 Control Box

For access, refer to section 15.1.
Hinge down the control box and unclip the rear cover to gain

access.
Remove relevant electrical connections from main PCB and

grommets from the control box.
MPORTANT: Support the control box whilst undoing the

hinges.
Remove the hinge securing screws accessed from beneath

the boiler and remove the control box, see diagram 15.10.

15.18 Fuse - Main PCB - Control Box

For access, refer to section 15.16.
The fuse is located at the top left hand corner of the main

PCB, see diagram 15.8.

15.19 Installer Interface Electrical Cartridge

Remove the Installer Interface securing screw accessed from

beneath the boiler.
Carefully pull down the electrical cartridge, disconnect the

cables.