1 boiler specification, Boiler specification – Glow-worm Flexicom hx User Manual

Page 7

Advertising
background image

7

1 Boiler Specification

14730

Diagram 1.2

BOILER SPECIFICATION

Lift weight

12hx

to

30hx

25kg (55Ib)

35hx

26.5kg (58.4Ib)

Total weight (installed)

12hx

to

30hx

28kg (62Ib)

35hx

29.5kg (65Ib)

Gas connection Ø O.D.

15mm. copper

Heating Flow and Return connection Ø O.D.

22mm. copper

Condensate connection Ø I.D.

21.5mm. plastic

Electrical supply

230V~50Hz

Electrical rating

60W fused 3A

IP clasification

IPX4D

Internal fuse rating on main PCB

2A

Gas supply (governed meter only) and cat.

G20 natural gas

Gas Category

I2H natural gas

Inlet gas working pressure

20mbar

Burner % CO2 case on

9.3 nominal

Burner % CO2 case off

9.3 nominal

12hx

15hx

18hx

24hx

30hx

35hx

m

3

/h

1.28

1.60

1.93

2.58

3.26

3.8

ft

3

/h

45

56.5

68.1

90.9

115

134

m

3

/h

0.99

0.99

0.99

0.99

0.99

0.99

ft

3

/h

35.1

35.1

35.1

35.1

35.1

35.1

PLEASE REFER TO THE COMMISSIONING SECTION

max.

12.1

15.1

18.2

24.4

30.8

35.8

min.

9.4

9.4

9.4

9.4

9.4

9.4

max.

12

15

18

24

30

35.0

min.

9.3

9.3

9.3

9.3

9.3

9.3

90.7

90.5

90.4

90.3

90.3

90.0

Approximate max. gas rate

after 10 mins. from cold

Heat input NETT Q = kW

Heat output P = kW

Approximate min. gas rate

after 10 mins. from cold

Approximate gas rate

at part load.

SEDBUK rating

Band A

Flue type (all models)

C

13

, C

33

, C

43

, C

53

NOx (all models)

Class 5