SYSTEM SETUP

27

5 - inStructor Patient monitor
The <Instructor’s Patient Monitor> shows the current physiological state of the simulation.

In Instructor Mode only, the patient monitor waveforms and parameters can be set directly by selecting and clicking the individual
waveform or numeric parameter with the mouse pointer arrow.

6 - eyeS
The <Eyes> window is used to configure the state of the eyes of the patient during simulation.

The Eyes animation is a real-time representation of the eyes of the Manikin. For more information on configuring the eyes see section:
Clinical Features.

7 – airway / breathing
The <Airway / breathing> tab shows the airway/breathing status of the patient, and is used to configure these settings. For more
information on configuring the airway and breathing, see section: Clinical Features.

8 – circulation & fluidS
The settings of the <Circulation & fluids> tab are used to control the pulses and rate of bleeding from the Manikin during simulation.

If the <Airway / breathing> is hidden, click on the tab name to access the window. For more information on configuring fluids see
Clinical Features.

Note: Bleeding is only available for SimMan Essential Bleeding and NOT for SimMan Essential.

9 – SoundS
The settings of the <Sounds> tab are used to control the body sounds and vocal sounds from the manikin.

To open the <Sounds> menu, click on the tab name. For more information on configuring sound settings see Clinical Features.

10 – technical StatuS
The <Technical Status> window provides information about the technical status of the SimMan Essential manikin system, including
battery life, wireless connection signal strength, blood tank drainage, communication channels in use and video recording.

3G View and Classic View

There are two view options when running a simulation in Instructor Mode:

inStructor mode 3g view

inStructor mode claSSic view

Classic view makes use of the Learner event libraries of previous SimMan versions; so that custom-made scenarios made with older
SimMan software can be used seamlessly with SimMan Essential and SimMan Essential Bleeding. Therefore SimMan Scenarios made
before SimMan Essential will by default display the Classic view after conversion.

Scenarios made for SimMan Essential and SimMan Essential
Bleeding will display the 3G view:

Recommended for experienced users of older SimMan
versions: