Figure 7-1 is a graph of a typical waveform that the ADSR function might generate, where the
line which moves across the graph represents the value of the assigned Prophesy parameter after a
string is plucked. Here you can see the role that each parameter plays in determining ADSR
operation.
———————————————————————————————————————————————————
1
Set up a controller assignment
Use the PAGE control to access the first Controller page, as shown
below.
( 1 ) CNTNUM
0
PARM
OFF
UPLIM
0
LOWLIM
0
Figure 7-1: Typical ADSR waveform
ADSR can be used with any Prophesy parameter. One of the many potential uses for ADSR is
the simulation of a wah pedal being pressed each time a string is plucked. To better illustrate the
setup and use of the ADSR function, the remainder of this section will detail the steps involved for
configuring ADSR for use with the
WAH FREQ
parameter.