g. Disable Auto Features

Skip this page. The Eizo monitor has no automatic features that require disabling.

h. Dynamic Range

Follow the instructions on the Dynamic Range page to adjust the monitor’s Contrast control as
high as possible without causing one of the red, green, or blue lines to become nonlinear. Do
not be concerned that the RGB lines are separated from each other at this point in the
calibration process.

Adjust the monitor’s Brightness control to produce the desired maximum luminance level.

i. Color Decoder

Skip this page. The Eizo monitor has no color decoder with its associated color and tint controls.

j. Resolution

Skip this page. The Eizo monitor has no controls that can degrade resolution.

2. Metered Calibration Section
In the Metered Calibration section of the SI Advanced Calibration workflow, step through the following
pages to calibrate the Eizo monitor’s 1D LUT (or RGB Gains) and color matrix:

a. Grayscale – 2pt

Perform this Grayscale – 2pt calibration step only if the Eizo monitor does not have a full 1D LUT
available. An available 1D LUT will be calibrated on the following CalMAN page.

On the Grayscale – 2pt page, you can optimize the Eizo monitor’s RGB Gain and RGB Black Level
controls. There is no need to set the Eizo Color Temperature control, as it is automatically set to
User when the RGB controls are adjusted. Click the CalMAN AutoCal button and select “2 Point
30, 100%” to automatically adjust these grayscale controls.

b. Grayscale/Gamma

On the Grayscale/Gamma page, CalMAN automatically adjusts the Eizo monitor’s output 1D LUT
to calibrate gamma and grayscale tracking. Click the CalMAN AutoCal button to start the
automatic calibration process.

Note: If the Eizo monitor does not have an internal 1D LUT, use the previous Grayscale – 2pt
page to calibrate the monitor’s RGB Gain controls.

c. CMS Calibration

On the CMS Color Gamut page, CalMAN automatically adjusts the Eizo monitor’s color matrix to
calibrate CMS. Click the CalMAN AutoCal button to start the automatic calibration process.

Note: When calibrating the Eizo monitor’s 1D LUT, a better final result is obtained by first
calibrating CMS, then Grayscale/Gamma, then repeating the CMS calibration.