b. Display Connect

On the Display Connect page, follow the instructions to make a USB connection from the
CalMAN computer to the Eizo monitor that is to be calibrated. Click the “Eizo Connect” button.

This USB connection will be used to load calibration data into the target monitor.

Note: If more than one Eizo monitor is connected to the computer, disconnect all the Eizo
monitors except for the one that you are currently calibrating.

c. Meter Setup

For monitors without a supported built-in meter, connect your external color meter to the
CalMAN computer.

On the Meter Connect page, click the Find Meter button. On the Find Meters dialog, select either
your Eizo display meter, or your externally connected meter if it is listed, then click Search. If
your external color meter is not listed on the Find Meters dialog, just click Search.

Under the Target Display Type drop down, if the Eizo monitor has wide color gamut that
“reproduces 97% of Adobe RGB color space,” select “LCD (LED Wide Gamut).” If the monitor is
not wide gamut, select “LCD (LED).”

d. Session Options

On the Session Options page, confirm that the listed monitor and display mode are correct. If
not, step back to the Select Monitor and Calibration Memory drop down, on the Calibration
Client Connect
page, to make the desired selection.

Make any desired changes to the default White Point and Gamma targets.

Note: This workflow defaults to PC (0-255) for Input Signal Levels. This is required to support 1D
LUT calibration.

2. Metered Calibration section
In the Metered Calibration section of the Monitor - Direct (EIZO/HP) workflow, step through the
following pages:

a. Pre-Calibration Capture

On the Pre-Calibration Capture page, you can measure the monitor’s performance before you
calibrate it. When you click the Read Series button, CalMAN measures the monitor’s grayscale
balance, the luminance at reference white, and the ColorChecker error across the monitor’s
color gamut.

b. Adjust Brightness

On the Adjust Brightness page, you can change the monitor’s luminance output by adjusting its
Brightness control. Click the CalMAN AutoCal button and input your desired White Level Target
to automatically adjust the Brightness control. Or, click the Read Continuous button and adjust
the software Brightness control in CalMAN to change the white level luminance.