13

SETUP MODE - MACHINE SETUP

NOTE: To gain access to Machine setup, press the Nexen logo

button while simultaneously pressing the STOP button and
hold them until SETUP ENABLE appears on the display.

1. Press the Select Upper button until you reach Setup

Mode (See Figure 12). The parameters in Setup Mode
are set when the machine is initially installed or when the
machine is modified. Press the plus or minus buttons to
select Machine. Then press Enter.

2. The lower display line will advance to Language (See

Figure 13). Press the plus or minus button to select the
desired language, then press Enter.

3. The lower display line will advance, prompting you to

select millimeters or inches (See Fig. 14). Press the plus
or minus button to select the desired measurement; then
press Enter.

4. The lower display line will advance, prompting you to

select wind or unwind (See Figure 15). Wind controls
tension during the increase in the diameter of a roll,
and Unwind controls tension during the decrease in the
diameter of a roll. Press the plus or minus button to select
WIND or UNWIND, then press Enter.

5. The lower display line will advance, prompting you to

select the type of sensor to be used. The selections are
Sonic, which stands for Ultrasonic Sensor; Prox, which
stands for proximity sensor, or Prox-Encod, which stands
for Proximity Sensor - Optical Encoder (See Figure 16).
Press the plus or minus button to select the proper type of
sensor, then press Enter.

NOTE: When the Prox-Encod combination is selected, the

lower display will advance, revealing the following (Counts:

00833/100 in [2540mm]). If you are using a Nexen Optical

Encoder this information is the Factory default setting, and

you can proceed to the next step by pushing Enter. If you

are using another Optical Encoder you will have to calculate

the number of pulses per 100 in [2540mm] of web length

and replace the default value (00833) with your calculated

value.

Example: The Nexen Optical Encoder is attached to a 12in

[305mm] circumference wheel. This wheel contacts a roller

that is moving at the same speed as the web. For every 12

in [305mm] of web that passes by, the Encoder produces

100 pulses. Use the following formula to calculate the new

number: (100 multiplied by number of pulses per revolution

of the encoder) divided by the number of inches of web length

per revolution of the encoder.

Example: (100 in. [2540mm] x 100 pulses per rev.) / 12 inches

[305mm] per rev. = 00833.

Press the plus or minus buttons to change the default value

to your calculated value, then press Enter. The upper display

line will now return to the Setup Mode.

FIGURE

SETUP MODE (OFF)

Job [Machine]

FIGURE 13

SET MACHINE

(OFF)

Language: English

FIGURE 14

SET MACHINE (OFF)

Millimeters [Inches]

FIGURE 15

SET MACHINE

(OFF)

[WIND] UNWIND

FIGURE 16

SET MACHINE

(OFF)

[Sonic] Prox Encod

FIGURE 17

SET JOB

(OFF)

[Edit] Load Save

Enter

Minus

Plus

SETUP PROCEDURE (continued...)

(continued...)

Advertising
This manual is related to the following products: