Nexen TCD600E 912145 User Manual

Page 17

Advertising
background image

FORM NO. L-20348-F-0705

17

SETUP MODE [Set Machine]

Language:

English

*

English

Millimeters

Inches

Inches

Wind

Unwind

Wind

Sonic

Prox

Prox Encod

Sonic

Counts:

(For Prox and Prox Encod Sensors Only)

00833/100 in

SETUP MODE [Set Job]
Wind Applications, Sonic Sensor

[Edit Job] (Parameters)

Full Roll:

060.00 in

Setpoint:

010.0 %

Hold Torque:

010.0 %

Strt Time:

003.0 sec

Taper:

000.0 %

Diam Hyst:

0.10 in

Min Dia Alrm:

006.00

Min Alarm:

NC

Max Dia Alrm:

050.00

Max Alarm:

NC

Accept Changes

(Yes or No)

Y [N]

Wind Applications, Prox Sensor

[Edit Job] (Parameters)

Full Roll:

060.00 in

Setpoint:

010.0 %

Hold Torque:

010.0 %

Strt Time:

003.0 sec

Taper:

000.0 %

IDiam:

006.00 in

Thick:

0.0050 in

Min Dia Alrm:

006.00

Min Alarm:

NC

Max Dia Alrm:

050.00

Max Alarm:

NC

Accept Changes

(Yes or No)

Y [N]

QUICK REFERENCE SETUP AND CALIBRATION WORKSHEET

DEFAULT

JOB 1

JOB 2

JOB 3

JOB 4

JOB 5

* Additional Languages include Spanish and French; other languages may be included later; contact Nexen for details.

Note: Refer to Glossary of Terms for explanations of the parameters.

Advertising