Connection examples: en, 15 str2 hardware manual – Applied Motion STR2 User Manual

Page 15

Advertising
background image

15

STR2 Hardware Manual

920-0059B

1/30/2014

Connecting an Input to a Switch or Relay

STR2

switch or relay

(closed=logic low)

EN

COM+

5-24

VDC

Power

Supply

-

+

Connection Examples: EN

Connecting another drive to EN

(When output closes, input closes)

Connecting an NPN Type Proximity Sensor to an input

(When prox sensor activates, input closes)

STR

EN

COM+

-

+

Si drive

OUT+

OUT–

5-24

VDC

Power

Supply

STR2

NPN

Proximity

Sensor

EN

COM+

output

+

5-24

VDC

Power

Supply

-

+

Advertising