Alarm Codes

In the event of a drive fault or alarm, the green LED will flash one or two times, followed by a series of red flashes. The pat-
tern repeats until the alarm is cleared.

404 Westridge Drive Watsonville, CA 95076

Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544

www.applied-motion.com

Power and Motor Connector

Signal Connector

Connector Diagrams

Code

Error

solid green

no alarm, motor disabled

flashing green no alarm, motor enabled

1 green, 3 red over temperature

2 green, 3 red internal voltage out of range

1 green, 4 red power supply voltage too high

2 green, 4 red power supply voltage too low

1 green, 5 red over current / short circuit

1 green, 6 red open motor winding

V+ V

A

B+ B

A+

STEP DIR

EN

OUT

+

OUT

COM+

920-0059B