STR2 Hardware Manual

920-0059B

1/30/2014

Step 6: Step Pulse Type

Most indexers and motion controllers provide motion commands in the “Step and Direction”

format. The Step signal pulses once for each motor step and the direction signal commands

direction. However, a few PLCs use a different type of command signal: one signal pulses once

for each desired step in the clockwise direction (called STEP CW), while a second signal pulses

for counterclockwise motion (STEP CCW). The STR drives can accept this type of signal if you

remove the drive cover and move jumper S3 from the “1-2” position to the “1-3” position. In

STEP CW/STEP CCW mode, the CW signal should be connected to the STEP input and the

CCW signal to the DIR input.

Step & Direction

STEP CW & STEP CCW