Led error codes, 34 swm24 hardware manual – Applied Motion SWM24IP-3EE User Manual

Page 34

Advertising
background image

LED Error Codes

Status LED SWM

The SWM24 drive+motor includes a red/green LED to indicate status. When the motor is enabled, the LED flashes green

slowly. When the green LED is solid, the motor is disabled.

Errors are indicated by combinations of red and green “flashes” as follows:

Code

Error

solid green

no alarm, motor disabled

flashing green no alarm, motor enabled

fast green

Q program running

1 red, 1 green motor disabled after a stall condition occurred

1 red, 2 green move attempted while drive disabled

2 red, 1 green ccw limit

2 red, 2 green cw limit

3 red, 1 green drive overheating

3 red, 2 green internal voltage out of range

3 red, 3 green blank Q segment

4 red, 1 green power supply overvoltage

4 red, 2 green power supply undervoltage

4 red, 3 green flash memory backup error

5 red, 1 green over current / short circuit

5 red, 2 green I/O occupied

6 red, 1 green open motor winding

6 red, 2 green bad encoder signal

7 red, 1 green serial communication error

7 red, 2 green flash memory error

34

SWM24 Hardware Manual

920-0068B

10/31/2013

Advertising