Current, 9swm24 hardware manual – Applied Motion SWM24IP-3EE User Manual

Page 9

Advertising
background image

Current

The maximum supply current required by the SWM24 is shown in the chart below with different power supply voltage

inputs. You will note in the chart that the Drive+Motor does not draw as much current as the motor itself. That’s because

the SWM24 uses switching amplifiers, converting a high voltage and low current into lower voltage and higher current.

The more the power supply voltage exceeds the motor voltage, the less current you’ll need from the power supply.

Also note that the current draw is significantly different at higher speeds depending on the torque load to the motor.

Estimating your current needs may require a good analysis of the load the motor will encounter.

SWM24-3 12V Power Supply Current

Motor Current: 6A/phase

0

0.5

1

1.5

2

2.5

0

10

20

30

40

50

Speed(RPS)

To

rq

ue

(N

.m

)

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

Am

ps

Torque

Supply Current

Supply Current

No Load

SWM24-3 24V Power Supply Current

0

0.5

1

1.5

2

2.5

0

10

20

30

40

50

Speed(RPS)

To

rq

ue

(N

.m

)

0.00

0.50

1.00

1.50

2.00

2.50

3.00

3.50

4.00

4.50

Am

ps

Torque

Supply Current

Supply Current

No Load

Motor Current: 6A/phase

9

SWM24 Hardware Manual

920-0068B

10/31/2013

Advertising