BLuDC-S,-Q Hardware manual

BLuDC-S,-Q Hardware manual

BLuDC-S,-Q Hardware manual

BLuDC-S,-Q Hardware manual

BLuDC-S,-Q Hardware manual

BLU

Servo

+

5-24

VDC

SUPPLY

-

CW LIMIT-

COM

CCW LIMIT-

Wiring a Mechanical Limit Switch
You can use normally open or normally closed limit switches. Either way, wire them as shown
here.

Wiring a Limit Sensor
Some systems use active limit sensors that produce a voltage output rather than a switch or relay
closure. These devices must be wired differently than switches.

If your sensor has an open collector output or a sinking output, wire it like this:

BLU Servo

+

DC

Power

Supply

Limit

Sensor

output

+

COM

CW LIMIT

If the sensor output goes low at the limit, select the option “closed” (in the software). If the output
is open, or high voltage, choose “open”.

Other sensors have sourcing outputs. That means that current can flow out of the sensor output,
but not into it. In that case, wire the sensor this way:

BLU Servo

+

DC

Power

Supply

Proximity

Sensor

output

+

CW LIMIT

COM