2.3.1 Controlling a Single Door or Gate

Relay 1 is typically used when the system will control a single door or vehicular gate operator. Note
that the electric strike and magnetic lock are each powered by their own power supply. Electric
strikes are connected through the normally open (NO) contact and magnetic locks are connected
through the normally closed (NC) contact.

2.3 RELAY WIRING (TYPICAL)

10 Relay 1 Common

11 Relay 1 Normally Closed

12 Relay 1 Normally Open

M a i n

Terminal

Strip

Relay 2 Common

Relay 2 Normally Closed

Relay 2 Normally Open

Relay 2 Terminal

C o n n e c t i o n s

Electric
Strike

M a g n e t i c
L o c k

G a t e
Operator

O R