1 remote programming, 2 remote relay activation, 3 relay check – DoorKing 1802 User Manual

Page 44: 2 system administrator

Advertising
background image

44

The administrator can perform the following operations from a remote location using a touch-tone
telephone. You must know the phone number of the system and the system master code.

5.2.1 Remote

Programming

1. Call the telephone number that the entry system is installed on. The system will answer

with a short tone (beep). Note: the number of rings before the system answers is
dependent on the programming in 3.1.8.

2. After the system answers, follow the desired programming steps in Section 3.

3. When complete, hang up. You cannot use 0# together to end the programming step from

a touch-tone telephone.

5.2.2 Remote Relay Activation

1. Call the telephone number that the entry system is installed on. The system will answer

with a short tone (beep). Note: the number of rings before the system answers is
dependent on the programming in 3.1.8.

2. Press



and enter the four-digit MASTER CODE

BBBB

(beep).

3. Press the desired tone open number

B

(beep). NOTE: Refer to 3.1.5 to determine

which tone open features have been programmed, i.e. momentary open, hold open,
release, hold open one hour and then release.

4. Hang

up.

5.2.3 Relay Check

The telephone entry system can be called and a check can be made to determine if any of the relays
in the system are in a "hold open" mode. This check can be useful if yourr gate (or door) is held open
and you suspect that the telephone entry system relay may be the cause.

1. Call the telephone number that the entry system is installed on. The system will answer

with a short tone (beep). Note: the number of rings before the system answers is
dependent on the programming in 3.1.8.

2. Press



and enter the four-digit MASTER CODE

BBBB

(beep).

3. The system will emit a series of short tones if the relay is in a continuous activation mode.

Relay 1 activated:

beep - pause - beep - pause . . .

Relay 2 activated:

beep beep - pause - beep beep - pause . . .

Relay 1 & 2 activated:

beep beep beep - pause - beep beep beep - pause . . .

4. Press the programmed tone number

B

to deactivate the relay (beep). The system will

automatically hang up.