2.3.2 Controlling a Gate Operator and Pedestrian Gate (or Door)

When controlling a gate operator and pedestrian gate (or door), relay 1 is typically used to control the
gate operator while relay 2 is typically used to control the door or pedestrian gate. Note that the
electric strike and the magnetic lock are powered from their own power supply. The normally open
(NO) contact is used for electric strikes and the normally closed (NC) contact is used for magnetic
locks.

A variation of this diagram is for the system to control two doors or two gates.

10 Relay 1 Common

11 Relay 1 Normally Closed

12 Relay 1 Normally Open

M a i n

T e r m i n a l

Strip

Relay 2 Common

Relay 2 Normally Closed

Relay 2 Normally Open

Relay 2 Terminal

C o n n e c t i o n s

Electric
Strike

M a g n e t i c
L o c k

G a t e
O p e r a t o r

A N D

O R