If the charger is attached and switched on, you
will see the battery voltage rise as the battery
charges. When the battery is fully charged you
will see the temperature rise and the charger
will switch-off when the rise equals 5°C.

One CHARGE is enough. It is possible to
raise the battery temperature by charging
three or four times in succession, which
raises temperature by 5°C each time. This
does not put any extra charge in the battery
or achieve anything useful.

To terminate INFO mode, press ESCape.

Automatic Battery Charging

When S4 is turned on, it charges the battery if
the "FUEL GAUGE" shows less than 75% full.
The charger will replenish the battery in less
than an hour. There is a temperature sensor in
contact with the battery. When it sees a 5°C
rise, the charge current turns off. Charging is
thus perfectly safe and S4 may be used
normally whilst being charged.