Dataman S4 User Manual

Page 31

Advertising
background image

DATAMAN S4 MANUAL

INFO KEY 31

Nicad Battery

The battery is capable of the following typical
performance when fully charged:

Standby 10ua - about 12 week’s

retention of program, data and
configuration. After that the Lithium cell
takes over.

Viewing 30ma - 20 hours of editing

(25% less via RS232)

Burning 180ma - 3 hours

programming - the actual number of
PROMS varies widely from about 100
oldest-type to 1000 latest-type

Emulating 100ma - 6 hours emulating

(depends on amount of access that the
target system makes and the load it
places on the data lines).


Real work is a combination of activities, of
course.
Early warning of battery discharge and
automatic shut-off operates if the battery falls
below 8.4 volts. Shutting-off is orderly - there
is no harm to any device being programmed
and no loss of data, provided S4 is recharged
within a few days.
When the charger is ON, 650ma a.c flows into
S4 and this will recharge the battery in about
an hour. A reasonable working capacity will be
restored in much less time.
Deep discharges and fast recharges make the
battery last longer than a trickle of charge
which maintains a fully charged battery all the
time.