J2, J3, J5, and J7 Termination Enable

J2, J3, J5, and J7 are 3-pin connectors that set the SCSI termination for each
SCSI channel. The Dell default is termination always enabled (OPEN.)
Table 10-2 displays the pinout.

J9, J10, J11, and J12 TERMPWR Enable

J9, J10, J11, and J12 are 2-pin connectors that enable TERMPWR to the
SCSI bus for each SCSI channel. The default is pins 1 and 2 shorted. Table
10-3 displays the pinout.

Ta b l e 1 0 - 2 . J 2 , J 3 , J 5 a n d J 7 Te r m i n a t i o n E n a b l e P i n o u t

Jumper

SCSI

Channel

SCSI

Termination
Controlled by
Software

SCSI

Termination
Always
Disabled

SCSI

Termination
Always Enabled

J2

0

Short pins 1-2

Short pins 2-3

OPEN (default)

J3

1

Short pins 1-2

Short pins 2-3

OPEN (default)

J5

2

Short pins 1-2

Short pins 2-3

OPEN (default)

J7

3

Short pins 1-2

Short pins 2-3

OPEN (default)

Ta b l e 1 0 - 3 . J 9 , J 1 0 , J 1 1 a n d J 1 2 T E R M P W R E n a b l e P i n o u t

Jumper

Term.
Power

Channel

Settings

J9

0

Short pins 1-2 to have the host PCI bus provide

TermPWR. This is the factory setting. Leave open to let

the SCSI bus provide TermPWR.

J10

1

Short pins 1-2 to have the host PCI bus provide

TermPWR. This is the factory setting. Leave open to let

the SCSI bus provide TermPWR.

J11

2

Short pins 1-2 to have the host PCI bus provide

TermPWR. This is the factory setting. Leave open to let

the SCSI bus provide TermPWR.

J12

3

Short pins 1-2 to have the host PCI bus provide

TermPWR. This is the factory setting. Leave open to let

the SCSI bus provide TermPWR.