Troubleshooting

207

X Logical
Drives Degraded

x number of logical

drives signed on in a

degraded state.

Make sure all physical drives

are properly connected and

are powered on. Run the

BIOS Configuration Utility

to find whether any physical

drives are not responding.

Reconnect, replace, or

rebuild a drive that is not

responding.

1 Logical Drive
Degraded

A logical drive signed

on in a degraded state.

Make sure all physical drives

are properly connected and

are powered on. Run the

BIOS Configuration

Manager to find out if any

physical drives are not

responding. Reconnect,

replace, or rebuild any drive

that is not responding.

Insufficient
memory to run
BIOS. Press any
key to
continue…

Not enough PERC 3

memory to run PERC

3 BIOS.

Make sure PERC 3 cache

memory has been properly

installed.

Insufficient
Memory

Not enough memory

on the PERC 3

adapter to support the

current configuration.

Make sure PERC 3 cache

memory has been properly

installed.

The following
SCSI IDs are
not responding:

Channel x:a.b.c

The physical drives

with SCSIO IDs a, b,

and c are not

responding on SCSI

channel x.

Make sure the physical drives

are properly connected and

are powered on.

Ta b l e 1 3 - 2 . B I O S B o o t E r r o r M e s s a g e s

(continued)

Message

Problem

Suggested Solution