Appendix, Understanding, System – Adtec digital DPI-1200 (version 01.04.08U) Manual User Manual

Page 50: File, Appendix c - understanding the dpi system log file

Advertising
background image

MDI or chaining port- if this port was used, move the

patch cord to a non- MDI or -chaining port.

Channel indicators are neither red
or green

The channel has been administratively disabled or
feature locked. Re-enable the port via the front panel

or command API, if unlocked

Channel indicators flash red and

yellow

The DPI has lost communication with the splicer for

that channel. Check the splicer configuration for that
channel and the splicer interface for issues with the

output.

Channel indicator flashes red during

insert and then goes back to green

There is a discrepancy between the splicer and the

DPI. Check the time sync and media being used.

Verification files show a status of

0013 “Time Out”

Check the timing sync between the DPI and the

splicer. Check the media to be inserted for proper
encoding and audio formats to the stream

Verification files show a status of
0023 “No Cue”

Check cue method being used. If DTMF or GPI, check
the connector cable running between the receiver

and DPI. If SCTE35, check the insertion stream and
splicer configuration to make sure that it is available

and used

NTP Clock will not sync to address

Check the NTP server to make sure that it is a Linux

stratum server and the time server daemon is
running.

Appendix C - Understanding the DPI System Log File

System Operators

CHNLMGR – Channel Manager
CMDL – Command Log
FTPC – File Transfer Protocol Client
MIRROR – Mirror Client
SCHED – Schedule Daemon
STRM – Stream Manager
TRGRD – Trigger Daemon