Onnecting devices to the, 9223k-d, ) hardware setup – Aviosys 9223K-D User Manual

Page 9: Setting up the device

Advertising
background image

- 9-

Ref#9223KD0001

4.) Hardware Setup

*Before setup the device make sure of the following:

1.) Make sure that all the package contents are all included if anything is missing please

contact the store or your distributor.

2.) Make sure the power adaptor is the correct specification.
3.) Make sure that all the cables are working correctly

Setting up the Device

Warning:

This part of the procedure can be very dangerous. Please follow instructions carefully

or consult an electrician or someone who is experienced in the field to assist in the part of the
procedure. Aviosys is not responsible for any damages to the device or harm caused by from
misuse, incorrect installation, and (or) dangerous environment.

Normally Closed Circuit (NC) or Normally Open Circuit (NO)

The 9223K-D consists of a total of four relays. Each of the relays on the board has the option to
pick whether this circuit will be normally closed (NC) or normally open (NO).

Each relay can support a voltage up to 250VAC / 30 VDC . & a current up to:
N.O .Maximum: 8 Amp
N.C. Maximum: 4 Amp

Advertising