4 safety parameters – BECKHOFF EK1914 User Manual

Page 17

Advertising
background image

Product description

EK1914

15

Permissible ambient temperature (operation)

0

to +55

Permissible ambient temperature
(transport/storage)

-25

to +70

Permissible air humidity

5 % to 95 %, non-condensing

Permissible air pressure
(operation/storage/transport)

750 hPa to 1100 hPa

Climate category according to EN 60721-3-3

3K3

Permissible level of contamination

level of contamination 2
(comply with the chapter Cleaning)

Impermissible operating conditions

TwinSAFE Bus Couplers must not be used under
the following operating conditions:

under the influence of ionizing radiation

in corrosive environments

in an environment that leads to
unacceptable soiling of the Bus Coupler

EMC immunity/emission

according to EN 61000-6-2 / EN 61000-6-4

Vibration / shock resistance

according to EN 60068-2-6 / EN 60068-2-27

Shocks

15 g with pulse duration 11 ms in all three axes

Protection class

IP20

Permitted operating environment

control cabinet or terminal box with minimum
protection class IP54 according to IEC 60529

Permissible installation position

see section Installation position and minimum
distances

Approvals

CE, TÜV SÜD, UL

3.4 Safety parameters

Key figures

EK1914

Lifetime [a]

20

Prooftest Interval [a]

not required

1)

PFH

2.64E-09

%SIL3

2.64%

PFD

3.92E-05

%SIL3

3.92%

MTTFd [a]

>100 (1470,59)

DC

98.56%, CAT4

SFF

>99%

Performance level

PL e

Category

4

HFT

1

Element classification*

Type A

*) Classification according to EN 61508-2:2010 (see chapters 7.4.4.1.2 and 7.4.4.1.3)

The TwinSAFE Bus Coupler can be used for safety-related applications within the meaning of EN ISO
13849-1 up to PL e (Cat4).

1)

Special proof tests during the entire service life of the TwinSAFE Bus Coupler are not required.