7 tested devices – BECKHOFF EK1914 User Manual

Page 30

Advertising
background image

Operation

28

EK1914

4.1.7 Tested devices

The following list contains devices that were tested together with the EK1914 TwinSAFE Bus Coupler.
The results only apply for the current device hardware version at the time of testing. The tests were
carried out in a laboratory environment. Modifications of these products cannot be considered here. If you
are unsure please test the hardware together with the TwinSAFE Bus Coupler.

The tests were carried out as function tests only. The information provided in the respective manufacturer
documentation remains valid.

Sensors:

Manufacturer Type

Comment

SICK

C4000

Safety light curtain

SICK

S3000

Safety laser scanner

Wenglor

SG2-14ISO45C1

Safety light grids

Leuze

lumiflex ROBUST 42/43/44

Safety light barriers

Schmersal

BNS250-11ZG

Safety switch

ifm

GM701S

Inductive safety sensor

Keyence

SL-V (with PNP cable set)

Safety light curtain

Actuators:

Manufacturer

Type

Comment

Beckhoff

AX5801

TwinSAFE Drive option card: safe restart lock

Siemens

SIRIUS Serie S00
3RT1016-1BB42

Contactor

Note

Recommended protective circuits

We recommend R/C or diode-based protective circuits for actuators.

Varistor-based protective circuits should not be used.