BECKHOFF EK1914 User Manual

Page 36

Advertising
background image

Operation

34

EK1914

4.3.3.1

Configuration of the EK1914 for light barriers, light grids, light curtains, etc.

The EK1914 also supports direct connection of contact-free protective devices with two self-testing
outputs such as light barriers, light grids, light curtains, laser scanners, etc.

CAUTION

Sensors with self-testing outputs

Only sensors with self-testing outputs and a maximum sensor self-test duration of
350 µs may be connected to the EK1914.


Parameter
To connect these sensors please set the following parameters for the EK1914 in the TwinCAT System
Manager:

Connect the two sensor signals to channels 1 and 2 and activate the entry asynchronous
repetition OSSD
or any pulse repetition for both the inputs used under the parameter Logic for
channel 1 and 2
. The difference between these settings is that with any pulse repetition
simultaneous tests of the OSSD signals up to 350 µs are allowed.

Switch the sensor test of the EK1914 to false for both the inputs used.

4.3.3.2

Configuration of the EK1914 for safety switching mats

The EK1914 also supports the direct connection of safety switching mats.

Parameter
To connect these safety mats please set the following parameters for the EK1914 in the TwinCAT System
Manager:

Connect the two sensor signals to channels 1 and 2 and activate the entry short cut channel x/y
is no module fault
for both the inputs used under the parameter Logic for channel 1 and 2.

Switch the sensor test of the EK1914 to true for both the inputs used.

Advertising