P.57 – BECKHOFF AX2500 User Manual
Page 57

8.14.1
Connection to a AX2500 master, 5 V signal level (X4)
You can link several AX2500 amplifiers in master-slave operation (encoder follower).
Up to 16 slave amplifiers can be controller by the master via the encoder output. The
SubD connector X4 is used for this purpose.
Frequency limit: 1 MHz, transition speed tv
£ 0.1 µsec
AGND (terminal X3/1) must be connected to the ground of the control system!
8.14.2
Connection to incremental encoder master with 24 V signal level (X3)
You can use this interface to set up the AX2500 as a slave following an encoder with a
24V signal level (master-slave operation). This application uses the digital inputs DIGI-
TAL-IN 1 and 2 on connector X3.
Frequency limit: 100 kHz, transition speed tv
£ 0.1 µsec
AGND (terminal X3/1) must be connected to the ground of the control system!
AX2500 Product Manual
57
BECKHOFF
06/2007
Electrical Installation
AX2500
AX2500
AX2500