Digital outputs (X3)
Technical characteristics
—
Ground reference is Digital-GND (DGND, terminal X1/4,5 on the master)
—
Alle digital outputs are floating
—
DIGITAL-OUT1 and 2 : Open-collector, max. 30 V DC, 10 mA
—
Update rate: 250 µs
Programmable digital outputs DIGITAL-OUT 1 / 2:
You can use the digital outputs DIGITAL-OUT1 (terminal X3/8) and DIGITAL-OUT2
(terminal X3/9) to output messages from pre-programmed functions that are stored in the
servo amplifier.
A list of the pre-programmed functions can be found in the Online Help.
If an input is freshly assigned to a pre-programmed function, then the data set must be
stored in the EEPROM of the servo amplifier, and the 24 V auxiliary supply of the servo
amplifier must be switched off and on again (to reset the amplifier software).