9.6
Error messages
Any errors that occur are shown in coded form by an error number in the LED display on
the front panel. All error messages result in the BTB/RTO contact being opened, the out-
put stage being switched off (motor loses all torque), and the holding brake is activated.
Number Designation
Explanation
A/I/P/E
Status Messages
Status messages, no error, see p. 89
. . .
Status Message
Updating the startup configuration
F00
no error
no error on the selected axis module
F01*
Heat sink temperature
Heat sink temperature too high
limit is set by manufacturer to 80°
F02*
Overvoltage
Overvoltage in DC bus link
limit depends on the electrical supply voltage
F03*
Following error
Message from the position controller
F04
Feedback
Cable break, short-circuit, short to ground
F05*
Undervoltage
Undervoltage in DC bus link
limit is set by manufacturer to 100V
F06
Motor temperature
Motor temperature too high or temp. sensor defect
limit is set by manufacturer to 145°C
F07
Internal voltage
supply
Internal amplifier supply voltages are out of tolerance
F08*
Overspeed
Motor runs away, speed is too high
F09
EEPROM
Checksum error
F10
Flash-EPROM
Checksum error
F11
Brake
Cable break, short-circuit, short to ground
F12
Motor phase
Motor phase missing (cable break or similar)
F13*
Internal temperature
Internal temperature too high
F14
Output stage
Fault in the power output stage
F15
I²t max.
I²t maximum value exceeded
F16*
Supply BTB/RTO
2 or 3 phases missing in the mains supply feed
F17
A/D converter
Error in the analog-digital conversion, normally caused
by extreme electromagnetic interferences.
F18
Regen
Regen circuit faulty or incorrect setting
F19*
Supply phase
A phase is missing in the mains supply power feed
F20
Slot fault
Slot error (hardware fault on interface card)
F21
Handling error
Software error on the interface card
F22
reserved
reserved
F23
CAN-bus off
Severe CAN bus communication error
F24
Warning
Warning is displayed as fault
F25
Commutation error
Commutation error
F26
Limit switch
Homing error (hardware limit switch activated)
F27
reserved
reserved
F28
External Trajectory
External position profile generator created a step, that
exceeded the maximum value
F29
Sercos Error
only in SERCOS systems
F30
Emergency timeout
Timeout emergency stop
F31
Macro
Macro program error
F32
System Error
system software not responding correctly
* = these error messages can be cleared without a reset, by using the ASCII command
CLRFAULT. If only one of these errors is present and the RESET button or the I/O
RESET function is used, only the CLRFAULT command will be executed.
More information to the messages can be found in the ASCII Object Reference
(Online Help), see parameter ERRCODE. Hints for removal can be found in the
Online help chapter "Trouble-Shooting".