Error messages

Any errors that occur are shown in coded form by an error number in the LED display on
the front panel. All error messages result in the BTB/RTO contact being opened, the out-
put stage being switched off (motor loses all torque), and the holding brake is activated.

Number Designation

Explanation

A/I/P/E

Status Messages

Status messages, no error, see p. 89

. . .

Status Message

Updating the startup configuration

F00

no error

no error on the selected axis module

F01*

Heat sink temperature

Heat sink temperature too high
limit is set by manufacturer to 80°

F02*

Overvoltage

Overvoltage in DC bus link
limit depends on the electrical supply voltage

F03*

Following error

Message from the position controller

F04

Feedback

Cable break, short-circuit, short to ground

F05*

Undervoltage

Undervoltage in DC bus link
limit is set by manufacturer to 100V

F06

Motor temperature

Motor temperature too high or temp. sensor defect
limit is set by manufacturer to 145°C

F07

Internal voltage
supply

Internal amplifier supply voltages are out of tolerance

F08*

Overspeed

Motor runs away, speed is too high

F09

EEPROM

Checksum error

F10

Flash-EPROM

Checksum error

F11

Brake

Cable break, short-circuit, short to ground

F12

Motor phase

Motor phase missing (cable break or similar)

F13*

Internal temperature

Internal temperature too high

F14

Output stage

Fault in the power output stage

F15

I²t max.

I²t maximum value exceeded

F16*

Supply BTB/RTO

2 or 3 phases missing in the mains supply feed

F17

A/D converter

Error in the analog-digital conversion, normally caused
by extreme electromagnetic interferences.

F18

Regen

Regen circuit faulty or incorrect setting

F19*

Supply phase

A phase is missing in the mains supply power feed

F20

Slot fault

Slot error (hardware fault on interface card)

F21

Handling error

Software error on the interface card

F22

reserved

reserved

F23

CAN-bus off

Severe CAN bus communication error

F24

Warning

Warning is displayed as fault

F25

Commutation error

Commutation error

F26

Limit switch

Homing error (hardware limit switch activated)

F27

reserved

reserved

F28

External Trajectory

External position profile generator created a step, that
exceeded the maximum value

F29

Sercos Error

only in SERCOS systems

F30

Emergency timeout

Timeout emergency stop

F31

Macro

Macro program error

F32

System Error

system software not responding correctly

* = these error messages can be cleared without a reset, by using the ASCII command
CLRFAULT. If only one of these errors is present and the RESET button or the I/O
RESET function is used, only the CLRFAULT command will be executed.

More information to the messages can be found in the ASCII Object Reference
(Online Help), see parameter ERRCODE. Hints for removal can be found in the
Online help chapter "Trouble-Shooting".