Cloud Electronics PM16 User Manual

Page 42

Advertising
background image

PM4/8/12/16 & PM4/8-SA Installation and User Guide v1.0

42

Terminating the Digital Paging Interface

The Cloud Digital Paging Interface must be correctly terminated at its ends for error-

free operation. In systems using a single PM connected to a host mixer via the digital
interface (such as the Cloud DCM-1), the terminations should be ON at both the PM
and the mixer. In systems with multiple PMs, only the mixer and the PM at the ‘end’ of
the chain should have their terminations set ON; ‘intermediate’ PMs should have their

terminations set to OFF.

CDPM

GAIN (dB)

IN

THRU

-10

+10

IN

OUT

OUT

Mixer

Mixer

OUT

OUT

Termination ON

Termination ON

Termination OFF

CDPM

IN THRU

CDPM

IN THRU

DCM-1 #2

DCM-1 #1

Termination ON

Termination

ON

Termination ON

Termination OFF

Termination

ON

CDPM

GAIN (dB)

IN

THRU

-10

+10

The termination is set in the PM with jumper J4. See “PCB layout diagrams” on page

49 for jumper locations. The factory default setting is for the termination to be set
ON. If the PM being confi gured is ‘mid-chain’, with both its CAN PORT IN and CAN

PORT OUT connectors in use, set the termination to OFF by removing the jumper.