Comtech EF Data CDM-500 User Manual

Page 23

Advertising
background image

Physical Description

CDM-500 Closed Network Satellite Modem

4–2

Rev.

1.3

Table 4-1- Front Panel Led Indicators

LED

Color

Condition

Red

A Unit Fault exists (Example: PSU fault)

Orange

No Unit Faults, but a Traffic Fault exists

Unit Status

Green

No Unit Faults, or Traffic Faults

Green

No Tx Traffic Faults

Transmit

Traffic

Off

A Tx Traffic fault exists
OR the Tx Carrier is in OFF state

Green

No Rx Traffic Faults (demod and Viterbi decoder are
locked, everything is OK)

Receive

Traffic

Off

An Rx Traffic fault exists (the demod may still be OK)

Green

The Unit is On Line, and carrying traffic

On line

Off

The Unit is Off Line (standby) - forced by externally
connected 1:1 or 1:N redundancy system

Orange

There is a Stored Event in the log, which can be viewed
from the front panel, or retrieved via the remote control
interface

Stored

Event

Off

There are no Stored Events

Orange

The Unit is in Remote Mode - local monitoring is
possible, but no local control

Remote

Off

The Unit is in Local Mode - remote monitoring is
possible, but no remote control

Orange

Framing on, EDMAC on, and unit defined as Slave

EDMAC

Mode

Off

Either no EDMAC, EDMAC Master, or Transparent
mode is selected

Orange

A Test Mode is selected (Example: IF Loopback)

Test Mode

Off

There is no Test Mode currently selected