Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments
for Command
or Response to
Query

Description of arguments
(note that all arguments are ASCII numeric codes,
that is, ASCII codes between 48 and 57)

Response to
Command (target to
controller)

Query
(Instruction
Code and
qualifier)

Response to
query (target
to controller)

Buffer Fill
State

N/A 2

bytes,

numerical

Query only.
Unit returns the value of the buffer fill state. Values
range from 1 to 99% .Example: BFS=33 (buffer fill
state is 33%) Returns 00 if demod unlocked.

N/A BFS?

BFS=xx

(see

description for
details of
arguments)

Rx BER

N/A

5 bytes

Query only.
Unit returns the value of the estimated corrected BER
in the form a.b x 10exp-c. Fist and second bytes are
value, 3rd and 4th bytes are the exponent.
Returns99999 if demod is unlocked.
Example: BER=4.8E3 (BER is 4.8 x 10-3)

N/A BER?

BER=a.bEc

(see description
for details of
arguments)

Redundancy
State

N/ A

1 byte, value of
0 or 1

Query only.
Returns the redundancy state of the unit, where:
0 = Off Line (forced into standby by 1:N or 1:1
Switch)
1= On Line (normal).
All other codes invalid.
Example: RED=1 (On Line)

N/A RED?

RED=x

(see description
for details of
arguments)

Local/Remote
Status

N/A

1 byte, value of
0 or 1

Query only.
Returns the local/remote status of the unit, where:
0 = local
1= remote
Example: LRS=1 (unit is in remote mode)

N/A LRS?

LRS=x

(see description
for details of
arguments)

Serial Number

SNO=

4 bytes
numerical

Command portion is FACTORY USE ONLY. Used
to set or Query the units 4 digit serial number.
0000 to 9999 Unit returns its S/N, in the form xxxx.
Example: SNO=1765

SNO= (message ok)

SNO?

SNO=xxxx
(see description
for details of
arguments)

Software
Revision

N/A 4

bytes,

numerical

Query only.
Unit returns the value of internal software revision
installed in the unit, in the form x.xx
Example: SWR=1.03 (Ver 1.03)

N/A SWR?

SWR=x.xx

(see description
for details of
arguments)

Equipment ID

N/A

6 bytes,
numerical

Query only.
Unit returns information concerning the equipment
identification, and the options fitted, in the form
aaaabc, where:
aaaa defines the Modem model number. Example:
0500 is CDM-500
b defines the IF band, with 1 = 70MHz, 2 = 140MHz
c defines RX only, with 1 = RX/TX, 2 = RX only
Ex: EID=050012 (CDM-500, 70 MHz band, RX
only)

N/A EID?

EID=aaaabc

(see description
for details of
arguments)