6.8.5

(MONIT) STORED EVENTS


STORED EVENTS: VIEW
CLEAR ALL (PRESS ENTER)

Select VIEW or CLEAR ALL, using the LEFT/RIGHT arrow keys, then press Enter.

If the user selects VIEW, the following screen is displayed:

6.8.6

(MON, EVENTS) VIEW


LOG23: 30/11/97 10:37:32
FT - DEMOD LOCK (UP/DWN)

Scroll backwards or forwards through the entries in the event log, using the UP/DOWN
arrow keys. Press ENTER or CLEAR to return to the previous menu. The event log can
store up to 100 events. When a fault condition occurs, it is time-stamped and put into the
log. Similarly, when the fault condition clears, this is also recorded, as shown below:


LOG24: 30/11/97 10:37:35
OK - DEMOD LOCK (UP/DWN)

If the user selects CLEAR ALL, the event log is cleared, and the user is taken directly
back to the previous menu. However, if there are faults present on the unit at this time,
they will be re-time-stamped, and new log entries will be generated.