Rx FEC Code
Rate

RCR=

1 byte, value of
1,3 or 7

Command or Query.
Rx FEC Code rate, where:
1 = Rate 1/2,
3 = Rate 3/4,
7 = Rate 7/8
All other codes invalid.
Example: RCR=1 (which is Rate 1/2)

RCR= (message ok)
RCR? (received ok,
but invalid argument
found)
RCR* (message ok,
but not permitted in
current mode

RCR? RCR=x

(same format as
command
argument)

Rx
Modulation
Type

RMD=

1 byte, value of
1or 2

Command or Query
Rx Modulation type, where:
1 = BPSK
2 = QPSK
All other codes invalid.
Example: RMD=1 (BPSK)

RMD= (message ok)
RMD? (received ok
but invalid argument
found)
RMD* (message ok,
but not permitted in
current mode)

RMD? RMD=x

(same format as
command
argument)

Rx Spectrum
Invert

RSI=

1 byte, value of
0 or 1

Command or Query.
Rx Spectrum Invert selection, where:
0 = Normal
1 = Rx Spectrum Inverted
All other codes invalid.

RSI= (message ok)
RSI? (received ok,
but invalid argument
found)
RSI* (message ok,
but not permitted in
current mode)

RSI?

RSI=x
(same format as
command
argument)

Rx
Descrambler

RDS=

1 byte, value of
0 or 1

Command or Query.
Rx De-scrambler state, where:
0 = Off
1 = On (V.35 in unframed mode, synchronous in
framed mode
All other codes invalid.
Example: RDS=1 (which is de-scrambler On)

RDS= (message ok)
RDS? (received ok,
but invalid argument
found)
RDS* (message ok,
but not permitted in
current mode)

RDS?

RDS=x
(same format as
command
argument)

Rx Demod
Acq Sweep
Width

RSW= 2

bytes,

numerical

Command or Query.
Rx ± acquisition sweep range of demodulator, in
kHz, ranging from ± 1 kHz to ± 30 kHz.
Example: RSW=09 (which is 9 kHz)

RSW= (message ok)
RSW? (received ok,
but invalid arguments
found)
RSW* (message ok,
but not permitted in
current mode)

RSW?

RSW=xx (same
format as
command
arguments)

Rx Clock
Mode

RCK=

1 byte, value of
0 or 1

Rx Clock mode, where:
Command or Query.
0 = Buffer disabled
1 = Buffer enabled
All other codes invalid.
Example: RCK=0 (which is buffer disable)

RCK= (message ok)
RCK? (received ok,
but invalid argument
found)
RCK* (message ok,
but not permitted in
current mode)

RCK?

RCK=x
(same format as
command
argument)

Advertising