4.3.1.6
FUNCTION SELECT: CONFIGURATION: RECALL
CONFIGURATION
RECALL
CONFIGURATION RECALL: 1, 2, 3, 4 or 5
The Configuration Recall menu allows the user to recall a previously saved configuration setup.
Upon entry, select memory location 1 through 5 by pressing [
↑
] or [
↓
]. Press <ENTER> to
execute the recall.
4.3.2
FUNCTION SELECT: MONITOR
FUNCTION SELECT
MONITOR
Press <ENTER > to review or edit the following sub-menus.
FUNCTION SELECT: MONITOR: RAW BER
RAW BER
2.4 E-3
Displays the current BER or “No Data” (if carrier is not locked).
Range: < m.m E-e to > m.m E-e.
Notes:
1. Low limit is based on performance.
2. High limit is based on data/code rate.
Press[
←] or [→] to move the flashing cursor, and [↑] or [↓] to increment or decrement the
selected kbps. Press <ENTER> to execute the change.