Comtech EF Data SNM-1001L User Manual
Page 143

SNM-1001L Satellite Modem
Revision 1
Front Panel Operation
MN/SNM1001L.IOM
4–79
FUNCTION SELECT: UTILITY: SYSTEM: REMOTE BAUD RATE
REMOTE BAUD RATE
9600 bps EVEN
The parity and baud rate settings of the modem are displayed.
To change the modem baud rate and/or parity, press <ENTER>. Press [
←] or [→] to position the
cursor over the parameter to be changed. Press [
↑] or [↓] to change the parameter. Once the
parameters are displayed as desired, press <ENTER> to set the baud rate and parity. The parity can
be set to EVEN, ODD, or NONE. The baud rate can be set from 150 to 19200 bps.
FUNCTION SELECT: UTILITY: SYSTEM: REMOTE ADDRESS
REMOTE ADDRESS
1
The current modem address is displayed (1 to 255).
To change the remote address, press <ENTER>. Press [
↑] or [↓] to make the selection. Press
[ENTER] to execute the change.
Note: Address 0 is reserved has a Global Address.
FUNCTION SELECT: UTILITY: SYSTEM: REMOTE TYPE
REMOTE TYPE
RS485 (2-WIRE)
Select EIA-485(2-Wire), EIA-485(4-Wire), or EIA-232.