Lnb current xxx ma, Lnb voltage xx volts – Comtech EF Data SNM-1001L User Manual
Page 105

SNM-1001L Satellite Modem
Revision 1
Front Panel Operation
MN/SNM1001L.IOM
4–41
IMPORTANT
Conditional: This menu available only when the optional Overhead
Card is installed.
Displays the current framing pattern bit error rate or “No Data” (if carrier is not locked). Monitors
the currently selected READ_ERROR function.
Range: < mm.m E-e to > mm.m E-e.
Notes:
1.
Low limit is based on performance.
2.
High limit is based on the data/code rate.
Frame Errors
Measured when framed modes of operation are active.
2047 Errors
Measured when the RX 2047 PATTERN (under the Configuration: Interface menu)
is tuned On.
FUNCTION SELECT: MONITOR: LNB CURRENT
LNB CURRENT
XXX mA
Monitors the LNB current or “LNB POWER OFF.”
Current displayed is 0 to 500 mA in 1 mA increments.
FUNCTION SELECT: MONITOR: LNB VOLTAGE
LNB VOLTAGE
XX VOLTS
Monitors the LNB voltage or “LNB VOLTAGE OFF.”
Voltage displayed is 0 to 24 VDC, in 1volt increments.