Interface configuration commands, B.3.3 interface configuration commands – Comtech EF Data SNM-1001L User Manual
Page 283

SNM-1001L Satellite Modem
Revision 1
Remote Control Operation MN/SNM1001L.IOM
B–9
Reed-
Solomon
Interleave
Value
Command:
Response:
Status:
Response:
<add/RRSI_xx'cr'
>add/RRSI_xx'cr''lf']
<add/RRSI_'cr'
>add/RRSI_xx'cr''lf']
Where: xx = 4, 8, or 16.
RX 8PSK 2/3
IESS-310
Operation
Command:
Response:
Status:
Response:
<add/R310_xxx'cr'
>add/R310_xxx'cr''lf']
<add/R310_'cr'
>add/R310_xxx'cr''lf']
Where: xxx = ON or OFF.
LNB Power
Command:
Response:
Status:
Response:
<add/LNB_xxx'cr'
>add/LNB_xxx'cr''lf']
<add/LNB_'cr'
>add/LNB_xxx'cr''lf']
Where: xxx = ON or OFF.
LNB Voltage
Command:
Response:
Status:
Response:
<add/LNBV_xxx'cr'
>add/LNBV_xxx'cr''lf']
<add/LNBV_'cr'
>add/LNBV_xxx'cr''lf']
Where: xxx = 13,18, or 24 Volts
LNB
Reference
Enable
Command:
Response:
Status:
Response:
<add/LNBR_xxx'cr'
>add/LNBR_xxx'cr''lf']
<add/LNBR_'cr'
>add/LNBR_xxx'cr''lf']
Where: xxx = ON or OFF.
LNB Power
Monitor Low
Current
Threshold
Command:
Response:
Status:
Response:
<add/LNBL_xxx'cr'
>add/LNBL_xxx'cr''lf']
<add/LNBL_'cr'
>add/LNBL_xxx'cr''lf']
Where: xxx = 0 to 500 in 1 mA steps
LNB Power
Monitor High
Current
Threshold
Command:
Response:
Status:
Response:
<add/LNBH_xxx’cr’
>add/LNBH_xxx’cr’’lf’]
<add/LNBH_’cr’
>add/LNBH_xxx’cr’’lf’]
Where: xxx = 0 to 500 in 1 mA steps
B.3.3 Interface Configuration Commands
Interface
Transmit
Overhead
Type
Command:
Response:
Status:
Response:
<add/ITOT_xxxxx'cr'
>add/ITOT_xxxxx'cr''lf']
<add/ITOT_'cr'
>add/ITOT_xxxxx'cr''lf']
Where: xxxxx = NONE or AUPC.
Interface
Receive
Overhead
Type
Command:
Response:
Status:
Response:
<add/IROT_xxxxx'cr'
>add/IROT_xxxxx'cr''lf']
<add/IROT_'cr'
>add/IROT_xxxxx'cr''lf']
Where: xxxxx = NONE or AUPC.
TX Driver
Type
Command:
Response:
Status:
Response:
<add/TXDR_xxxxx'cr'
>add/TXDR_xxxxx'cr''lf']
<add/TXDR_'cr'
>add/TXDR_xxxxx'cr''lf']
Where: xxxxx = V35, RS422, or RS232.
RX Driver
Type
Command:
Response:
Status:
Response:
<add/RXDR_xxxxx'cr'
>add/RXDR_xxxxx'cr''lf']
<add/RXDR_'cr'
>add/RXDR_xxxxx'cr''lf']
Where: xxxxx = V35, RS422, or RS232.
Transmit
Clock
Command:
Response:
Status:
Response:
<add/TC_xxx'cr'
>add/TC_xxx'cr''lf']
<add/TC_'cr'
>add/TC_xxx'cr''lf']
Where: xxx = INT (internal SCT clock), EXT
(external TX terrestrial clock), REF (external
clock-reference frequency).
External
Clock-
Reference
Frequency
Command:
Response:
Status:
Response:
<add/ERF_nnnnn.n'cr'
>add/ERF_nnnnn.n'cr''lf']
<add/ERF_'cr'
>add/ERF_nnnnn.n'cr''lf']
Where: nnnnn.n = 8.0 to 10000.0 (external clock
frequency in kHz).
Transmit
Clock
Phase
Command:
Response:
Status:
Response:
<add/TCP_xxxx'cr'
>add/TCP_xxxx'cr''lf']
<add/TCP_'cr'
>add/TCP_xxxx'cr''lf']
Where: xxxx = NRM (normal clock phasing), INV
(inverted clock phasing), AUTO (automatic clock
phasing).
Buffer Clock
Command:
Response:
Status:
Response:
<add/BC_xxx'cr'
>add/BC_xxx'cr''lf']
<add/BC_'cr'
>add/BC_xxx'cr''lf']
Where: xxx = INT (internal SCT clock), EXT
(external TX terrestrial clock), SAT (receive
satellite clock), REF (external clock-reference
frequency), INS (insert clock).