Comtech EF Data SNM-1001L User Manual
Page 284

SNM-1001L Satellite Modem
Revision 1
Remote Control Operation MN/SNM1001L.IOM
B–10
Receive
Clock
Phase
Command:
Response:
Status:
Response:
<add/RCP_xxx'cr'
>add/RCP_xxx'cr''lf']
<add/RCP_'cr'
>add/RCP_xxx'cr''lf']
Where: xxx = NRM (normal clock phasing), INV
(inverted clock phasing).
Baseband
Loopback
Command:
Response:
Status:
Response:
<add/BBL_xxx'cr'
>add/BBL_xxx'cr''lf']
<add/BBL_'cr'
>add/BBL_xxx'cr''lf']
Where: xxx = ON or OFF.
Interface
Loopback
Command:
Response:
Status:
Response:
<add/ILB_xxx'cr'
>add/ILB_xxx'cr''lf']
<add/ILB_'cr'
>add/ILB_xxx'cr''lf']
Where: xxx = ON or OFF.
Interface
Loop Timing
Command:
Response:
Status:
Response:
<add/ILT_xxx'cr'
>add/ILT_xxx'cr''lf']
<add/ILT_'cr'
>add/ILT_xxx'cr''lf']
Where: xxx = ON or OFF.
Interface
Buffer Size
Buffer size programming is supported in two formats; bits, or milli-seconds. The selected format must be chosen
using the buffer programming command (IBP_). If the buffer is to be programmed in milli-seconds and
plesiochronous slips are required use the receive framing structure command (IRFS_) to define the proper framing
format.
Interface
Buffer Size
(Bit Format)
Command:
Response:
Status:
Response:
<add/IBS _nnnnnn'cr'
>add/IBS _nnnnnn'cr''lf']
<add/IBS _'cr'
>add/IBS _nnnnnn'cr''lf']
Where: nnnnnn = 32 to 262144, in 16 bit
increments.
Interface
Buffer Size
(Milli-
second
Format)
Command:
Response:
Status:
Response:
<add/IBS _nn'cr'
>add/IBS _nn'cr''lf']
<add/IBS _'cr'
>add/IBS _nn'cr''lf']
Where: nn = 0 to 99 (buffer size in milli-seconds).
Note: For Drop & Insert:
1.
nn = 7.5, 15, or 30 (milli-seconds) for
E1CAS format.
2.
nn = 6, 12, 24, or 30 (milli-seconds) for
T1S/T1ESFS format.
3.
nn = 1, 2, 4, 8, 16, or 32 (milli-seconds)
for all other D&I formats.
Interface
Buffer
Center
Command:
Response:
<add/IBC_'cr'
>add/IBC_'cr''lf']
Interface
Buffer
Program-
ming
Command:
Response:
Status:
Response:
<add/IBP_xxxx'cr'
>add/IBP_xxxx'cr''lf']
<add/IBP_'cr'
>add/IBP_xxxx'cr''lf']
Where: xxxx = BITS or MS (milli-seconds).
Interface
Receive
Farming
Structure
Command:
Response:
Status:
Response:
<add/IRFS_ff_ssss'cr'
>add/IRFS_ff_ssss'cr''lf']
<add/IRFS_ff'cr'
>add/IRFS_ff_ssss'cr''lf']
Where:
ff = T1 or E1 (frame type).
ssss = NONE or G704 (framing structure).
Interface
Substitute
Pattern
Command:
Response:
Status:
Response:
<add/ISP_xxxxxx'cr'
>add/ISP_xxxxxx'cr''lf']
<add/ISP_'cr'
>add/ISP_xxxxxx'cr''lf'
Where: xxxxxx = ON or OFF.
Note: Transmit 2047 Pattern.
Interface
Read Error
Select
Command:
Response:
Status:
Response:
<add/IRE_xxxxxx'cr'
>add/IRE_xxxxxx'cr''lf']
<add/IRE_'cr'
>add/IRE_xxxxxx'cr''lf']
Where: xxxxxx = ON or OFF.
Note: Receive 2047 Pattern.
Transmit
Data Fault
Command:
Response:
Status:
Response:
<add/TDF_xxxx'cr'
>add/TDF_xxxx'cr''lf']
<add/TDF_'cr'
>add/TDF_xxxx'cr''lf']
Where: xxxx = NONE, DATA, or AIS.
Receive
Data Fault
Command:
Response:
Status:
Response:
<add/RDF_xxxx'cr'
>add/RDF_xxxx'cr''lf']
<add/RDF_'cr'
>add/RDF_xxxx'cr''lf']
Where: xxxx = NONE, DATA, or AIS.