EQ90 REV 2 ERRATA A.DOC

1

Errata A

Comtech EFData Documentation Update


Subject:

Changes to Table 2-2. Summary Alarm Interface Connector J3 Pin
Assignments


Date:

October 18, 2000

Document:

EQ90 Group Delay/Amplitude Equalizer Installation and Operation
Manual, Rev. 2, dated June 14, 1998

Part Number:

MN/EQ90.EA2

Collating Instructions:

Attach this page to page 2-5


Comments:

The following changes provide additional Table 2-3 and updates to paragraph 2.3.1. This
information will be incorporated into the next revision.

Change Specifics:

Table 2-3. Summary Alarm Interface Connector J3 Pin Assignments

Pin No.

Assignment

1,2

Not Used

3

Normally Open (Equalizer Operational). Referenced to pin 4.

4 Common

5,6 Not

Used

7

Alarm Out (Open, Equalizer Operational). Referenced to pin 8.

8 Alarm

Common

9

Normally Closed (Equalizer Operational). Referenced to pin 4.

2.3.1 Channel Monitor

The alarm monitor output connector (J3) provides a summary fault status output to a summary
alarm panel, or annunciator type device, or redundancy switching equipment. Refer to Table 2-3
for pin assignments.