Comtech EF Data EQ90 Series User Manual

Page 51

Advertising
background image

EQ90 Amplitude Equalizer

Operation

Rev. 2

3-27

At this point, the SLP ADJ (7, Figure 3-3) potentiometer of the slope equalizer can be
readjusted to minimize the amplitude variations in the system as follows:

1. Connect a -20 dB IF output of a MLA transmitter to the equalizer IF input

connector.


2. Adjust GAIN ADJ potentiometer (6, Figure Chapter 3-3) for +15 dB of gain.

3. Adjust the SLP ADJ potentiometer (7, Figure Chapter 3-3) so the output of the

module as measured on the MLA receiver presents a flat response.

Note: The slope adjusts resistor provides for up to

±

3.0 dB of positive or

negative amplitude slope adjustment range.

Advertising