Specification, 3 specification – Comtech EF Data EQ90 Series User Manual

Page 16

Advertising
background image

Introduction

EQ90 Amplitude Equalizer

1–4

Rev. 2

1.3 Specification

Refer to Table Chapter 1-1 for the electrical and operational characteristics of the
equalizer.

Table Chapter 1-1. Electrical Specifications and Operational

Characteristics

Characteristic

Specification

IF Input

Frequency

70 MHz

±

18 MHz

140 MHz

±

36 MHz

Level

-15 dBm maximum (single carrier)
-18 dBm maximum. (multi-carrier composite)

Impedance

75

, unbalanced

Return Loss

20 dB

IF Output

Frequency

70 MHz

±

18 MHz

140 MHz

±

36 MHz

Level

0 dB nominal

Impedance

75

, unbalanced

Return Loss

20 dB

Input to Output

Gain

15 dB nominal

Amplitude Response

Adjustable to

±

0.15 dB

1 dB Compression

+8 dBm

Third Order Intercept Point

+18 dBm

Group Delay
(All Sections Off)

< 2 ns

Amplitude Equalization
Adjustment Range

±

3 dB/36 MHz minimum (70 MHz)

±

3 dB/72 MHz minimum (140 MHz)

Delay Equalization Adjustment Range/per section
70 MHz

< 15 ns/36 MHz
>40 ns/36 MHz

140 MHz

< 10 ns/72 MHz
> 30 ns/72 MHz

IF Fail Trip Point

Approx. -20 dBm

Fault/Status Type

Relay contact output
1 Form ‘C’
1 Form ‘A’

Primary Power Requirements

Voltage

84 to 265 VAC

±

10%

Frequency

47 to 63 Hz

Power Consumption

10 VA/Nominal

Advertising